How to Choose a Dual Run Capacitor: 35/5, 40/5, 45/5 and 70/5 Guide

Your air conditioner hums, but the fan and compressor stay still. In many cases, a weak dual run capacitor causes that exact symptom. This guide compares four GuuYebe values, so you can match your old part and fix the unit for under $12.

First, read the label on your old capacitor. Next, match both MFD numbers and the voltage rating exactly. For example, a 45/5 MFD part needs a 45/5 MFD replacement. Order the 45/5 dual run capacitor at GuuYebe if that value matches your label. Also, this guide covers the 35/5, 40/5 and 70/5 values below.

What Is a Dual Run Capacitor?

A dual run capacitor holds two capacitors in one round metal can. One side serves the compressor, and the other side serves the fan motor. As a result, one part starts and runs both motors in a residential AC condenser.

Three terminals sit on top of the can. HERM connects to the compressor, FAN connects to the fan motor, and C is the common terminal. In addition, the label lists two MFD numbers, such as 45/5. The first number feeds the compressor, and the second number feeds the fan.

GuuYebe builds these parts in the round CBB65 design with metallized polypropylene film. Also, each one carries a 370/440VAC rating, a 50/60Hz rating, and a ±6% tolerance. Finally, the operating range runs from −40°C to +70°C, so the part holds up in a hot condenser cabinet.

For background on other capacitor types, see our electrolytic capacitor values guide. It covers uF and voltage ratings for TV power board repairs.

The Four Values at a Glance

All four values share the same build, rating, and terminals. Only the capacitance differs. In total, the full set costs $42.48.

Value HERM (compressor) FAN Voltage Price
35/5 MFD 35 MFD 5 MFD 370/440VAC $9.88
40/5 MFD 40 MFD 5 MFD 370/440VAC $10.88
45/5 MFD 45 MFD 5 MFD 370/440VAC $9.86
70/5 MFD 70 MFD 5 MFD 370/440VAC $11.86

35/5 Dual Run Capacitor — $9.88

35/5 dual run capacitor CBB65 round AC capacitor

The 35/5 value is the smallest rating in this set. First, check your old label for “35/5” or “35+5”. Next, confirm the 370/440VAC rating. Then order the part if both numbers match. Buy the 35/5 capacitor at GuuYebe.

40/5 Dual Run Capacitor — $10.88

40/5 dual run capacitor CBB65 round AC capacitor

The 40/5 value sits between the 35/5 and 45/5 values. First, read the HERM number on your old part. Next, check that the FAN number reads 5 MFD. Then confirm the voltage rating before you order. Buy the 40/5 dual run capacitor at GuuYebe.

45/5 Dual Run Capacitor — $9.86

45/5 dual run capacitor CBB65 round AC capacitor

The 45/5 value is the lowest price in this set at $9.86. First, match the 45 MFD compressor number to your old label. Next, match the 5 MFD fan number. Then check the 370/440VAC rating. Buy the 45/5 dual run capacitor at GuuYebe.

70/5 Dual Run Capacitor — $11.86

70/5 dual run capacitor CBB65 round AC capacitor

The 70/5 value is the largest rating in this set. First, look for “70/5” or “70+5” on the old can. Next, confirm the fan side reads 5 MFD. Then check that the can fits the mounting strap. Buy the 70/5 capacitor at GuuYebe.

How to Pick the Right Dual Run Capacitor

First, read the old label and write down both MFD numbers. Next, match the HERM number exactly to the new part. Then match the FAN number exactly as well. Also, check the voltage rating on the label. Finally, measure the can and confirm it clears the mounting strap.

Do not swap in a different MFD value. For example, a 40/5 part cannot replace a 45/5 part. In addition, never fit a part with a lower voltage rating than the old one. A 370/440VAC part can replace a 370VAC part. The reverse is not safe.

Safety First: Discharge Before You Touch It

Capacitors store charge after the power goes off. First, kill the breaker for the condenser unit. Next, discharge the terminals with an insulated tool. Then photograph the wiring before you remove anything. HERM, FAN and C must land on the same terminals when the new part goes in.

Frequently Asked Questions

Can I replace a 45/5 capacitor with a 40/5 one?
No. Match both MFD numbers and the voltage rating exactly to the old label. A mismatched value can leave the compressor short on starting power, so the unit may hum and stall.

What does 370/440VAC mean?
It is the voltage rating of the part. A 370/440VAC part can replace a 370VAC part. Never fit a part with a lower voltage rating than the old one.

How do I know the old capacitor failed?
Look for a swollen or bulging top, oil stains, or a unit that hums but will not start. A swollen or weak capacitor is the top cause of a humming unit that will not start. In addition, a meter with a capacitance mode can test the value directly.

Four values cover most residential condensers. First, read your old label. Next, pick the matching value above. Finally, order your dual run capacitor from GuuYebe and get the unit running again.

Related Blogs